Table 1. Measurements of the Surface Tension of Liquid UO2 at the Melting Point

Surface Tension, J m-2

Method

Experimenter Reference

0.615 ± 0.180

liquid drop measurements Schins

[2]

0.441 ± 0.210

liquid meniscus shape measurements Bates

[4]

0.445 ± 0.210

droplet photographs Christensen

[3]

0.550. ± 0.210

droplet photographs Christensen

[3]

0.420*

shape of frozen menisci Chasanov

[6]



*Not included in the determination of the recommended surface tension.